Row of industrial sectional panelled loading bay doors
Insulated Industrial Access

Sectional
Panelled Doors.

Made-to-measure overhead doors that combine thermal performance, daylight, appearance and efficient use of the building around the opening.

Multiple Lift TypesTracks arranged around the building
Insulated PanelsFor controlled internal environments
RAL ColoursCoordinate with your building
Thermal protection Flexible lift geometry Optional vision panels RAL colour choices
Designed Around the Opening

Performance Above and Beyond the Doorway.

A sectional door opens vertically in connected insulated panels, then follows tracks into the building instead of swinging out into the vehicle or pedestrian area.

This makes it particularly useful where space in front of the opening must remain clear. The track system can be configured to follow the roof, rise vertically or work around available headroom, steelwork and building services.

EVICK surveys the complete opening and surrounding structure before recommending panel construction, lift type, operation, glazing, controls, safety devices and finish.

Large white sectional door with rows of vision panels
Sectional panels with vision windows for daylight and visibility.
Why Choose Sectional?

Suited to Buildings Where Performance Matters.

A sectional door is often selected when the opening needs more than a basic security barrier.

Temperature Control

Insulated panels help reduce heat transfer and support warehouses, workshops and controlled environments.

Clear External Space

Vertical opening keeps the apron and approach clear because no leaf swings into the working area.

Building Flexibility

Different track arrangements make use of roof height, slopes and available internal space.

Light & Visibility

Vision panels can introduce daylight and help users see people, vehicles or activity beyond the door.

Controlled Movement

Guided panel travel can provide a refined solution for frequently used industrial entrances.

Professional Appearance

Panel profiles, window layouts and colour choices can complement modern commercial buildings.

Lift & Track Arrangements

Make Use of the Space You Already Have.

The lift arrangement controls how the door panels travel after leaving the opening. Selecting it correctly protects usable space and helps the door work around the structure.

Standard liftTracks turn beneath a conventional horizontal ceiling area.
Low-headroom liftFor restricted clearance above the structural opening.
High liftRaises the door vertically before following the roof.
Inclined liftTracks can follow a sloping roof construction.
Vertical liftPanels rise vertically where sufficient height is available.

Drum position, shaft location and exact track geometry depend on dimensions, structure, services, operation and manufacturer design. These are confirmed after survey.

Diagram showing standard, low, high, inclined and vertical sectional door lift arrangements
Typical lifting arrangements. Final design is project-specific.
Insulated sectional door panel construction and thermal features
Insulated Panel Construction

Help Protect the Internal Environment.

Sectional door leaves are built from connected sandwich panels. Steel faces provide the external surfaces while the insulated core improves stiffness and thermal performance.

  • Insulated panel options selected for the building requirement.
  • Seals around panel joints, guides, lintel and threshold.
  • Optional anti-finger-trap panel profiles where specified.
  • Window and personnel-access options considered during design.

Thermal values vary with panel thickness, door size, glazing, seals and installation. Project performance should be confirmed in the final product specification.

Finishes & RAL Colours

Match the Door to Your Building.

Standard colours provide an efficient specification, while selected RAL finishes allow the door leaf to coordinate with cladding, brand colours or architectural details.

RAL 9010Pure WhiteRAL 9002Grey WhiteRAL 7016AnthraciteRAL 5011Steel BlueRAL 5010Gentian BlueRAL 6005Moss GreenRAL 3000Flame RedRAL 9005Jet Black

Colour is only part of the finish.

Availability can depend on the chosen panel, coating system, manufacturer and project quantity. Physical samples should be used for final approval because screens and photographs cannot represent RAL colours precisely.

EVICK can also discuss panel texture, rib profile, frame and track finish, window arrangement and external detailing.

Complete Project Support

From Survey to Future Servicing.

01

Survey

Opening, structure, roof, headroom, services, access and operating needs are assessed.

02

Specify

Panels, lift type, operation, windows, controls, safety and colour are agreed.

03

Manufacture

The door is produced to the confirmed dimensions and selected configuration.

04

Install

Installation and commissioning are coordinated safely around the building programme.

05

Support

Planned maintenance and responsive repair support help protect reliable operation.

Plan Your Door

Find the Right Sectional Door for Your Building.

Book a free site survey to discuss the opening, lift arrangement, insulation, glazing, operation and preferred finish.